PDF files require Acrobat Reader
to view them.
Click above to download it
for free.
|
 |

STF Series of Active Tracking Filters®
Low voltage/high frequency noise is caused by everyday events such as turning on machinery, motors, or equipment. Although noise is less dramatic than high voltage transients, the long term effects of these frequent disturbances can be as damaging. Filtering systems such as SolaHD Active Tracking Filters provide clean AC power by eliminating lower voltage noise.
The SolaHD STF Series offers the original active tracking technology to guard against commonly occurring, but
very damaging, lower energy transients. Offering excellent noise reduction, the filter continuously tracks the input
AC power line and responds instantly upon detecting
extraneous high frequency noise.
The STF Series eliminates low voltage/high frequency noise via a low-pass or L-C filter. These filters are used for low energy, high frequency noise reduction and consist of a series of inductors, capacitors and resistors. STFs are load dependent which means that the series inductors located on each phase and neutral conductors are sized to handle the maximum current draw on the line. These inductors together with the capacitors and resistors form a circuit capable of absorbing a large bandwidth of noise.
These devices are designed to meet UL 1283, and CSA C22.2 for Electromagnetic Interference Filters. STFs attenuate or reduce the amplitude of noise to a minimum of 40dB that occurs in a frequency range of 50KHz to 50MHz. STFs provide the industry’s best IEEE Category “A” protection, typically reducing normal mode transients to +/- 5 volts.
Built to meet your unique requirements, these filters are available in a multitude of voltage and phase configurations. They are hardwired and designed for years of trouble free operation requiring little or no operator intervention after installation.
Active Tracking® Filters are one part of a total power quality solution. They can be used alone or in conjunction with other SolaHD products to solve more complex power quality problems.
On this page: Features, Applications, Related Products, Specifications, Selection Table, Design Styles
Printable versions of the following sections are available by selecting
one of the pdf files to the left.
- Non degrading, series filter technology for
total durability
|
- UL 1283 Listed or
Recognized (Single Phase models), CSA
|
- High Frequency Noise filter, RLC Low-Pass filter
|
- Three Phase applications up to 200 Amp
|
- Attenuates noise to 40dB in frequency range of 50KHz to 50MHz
|
- Operating Temperature from -40°C to +45°C
|
|
|
|
- MTBF greater than 100,000 Hours, Mil 217F
|
|
|
Description
|
120 VAC Models |
240 VAC Models |
480 VAC Models |
| Input Voltage
|
0-150 VRMS |
0-275 VRMS |
0-520 VRMS |
Line Frequency |
50/60 Hz |
Transient Attenuation
Response Time |
Instantaneous |
| Meant Time Between Failure (MTBF) |
Greater than 100,000 Hours (MIL 217F) |
| Packaging |
Single phase units through 30 Amps housed in black, high impact plastic case, vacuum impregnated magnetics, epoxy encapsulated; single phase greater than 30 Amps, 480 VAC, and three phase units housed in NEMA 12 enclosures |
| Operating Temperature |
-40°C to +45°C Derate Linearly to 60% at +70ºC |
| Load Surge Current Rating |
10m Sec: 5 x Nominal |
| 1 sec : 3 x Nominal |
| 5 sec: 2 x Nominal |
| Transient Reduction |
Minimum of 40dB from 50kHz through 50MHz. Attenuation is greater than 50dB to the surge withstand capability ringwave test IEEE C62.41, Category “A” (IEEE Category A Ringwave 6 kV, 200A, 100 kHz) and “B” (IEEE Category B Ringwave 6 kV, 500A, 100 kHz). |
| Safety |
ANSI / UL1283, CAN/CSA C22.2 No 8. Listed or
Recognized “Electromagnetic Interference Filters” |
Catalog
Number |
Amps |
Min Wire Size
(AWG Suggested) |
Fuse/Circuit
Breaker Ampacity |
Case Dim.
(inch) |
Mounting Flange
Dims
(in) |
Weight
(lbs) |
Fig. |
| Suggest |
Max |
A x B x C |
D x E x F |
Single-Phase Models (120 VAC)*
With barrier strip at input & output |
STF0025-10 |
2.5 |
26 |
2.5A |
3.125A |
4.0 x 2.88 x 1.81 |
4.38 x 2.12 x 5.31 |
2.0 |
1 |
STF0050-10N |
5.0 |
22 |
5A |
6.25A |
4.0 x 2.88 x 1.81 |
4.38 x 2.12 x 5.31 |
2.0 |
1 |
STF0075-10N |
7.5 |
18 |
7.5A |
9.375A |
4.75 x 4.75 x 2.35 |
5.25 x 3.5 x 6.25 |
3.0 |
1 |
STF0150-10N |
15.0 |
14 |
15A |
18.75A |
6.25 x 4.75 x 2.35 |
6.75 x 3.5 x 7.75 |
5.0 |
1 |
STF0200-10N |
20.0 |
12 |
20A |
25A |
7.75 x 4.75 x 2.35 |
8.25 x 3.5 x 9.0 |
7.0 |
1 |
STF0300-10N |
30.0 |
10 |
30A |
37.5A |
7.75 x 4.75 x 2.35 |
8.25 x 3.5 x 9.0 |
8.0 |
1 |
Single-Phase Models (240 VAC)*
With barrier strip at input & output |
STF0025-24L |
2.5 |
26 |
2.5A |
3.125A |
4.0 x 2.88 x 1.81 |
4.38 x 2.12 x 5.31 |
2.0 |
1 |
STF0050-24L |
5.0 |
22 |
5A |
6.25A |
4.0 x 2.88 x 1.81 |
4.38 x 2.12 x 5.31 |
2.0 |
1 |
STF0075-24L |
7.5 |
18 |
7.5A |
9.375A |
4.75 x 4.75 x 2.35 |
5.25 x 3.5 x 6.25 |
3.0 |
1 |
STF0150-24L |
15.0 |
14 |
15A |
18.75A |
7.75 x 4.75 x 2.35 |
8.25 x 3.5 x 9.0 |
5.0 |
1 |
STF0200-24L |
20.0 |
12 |
20A |
25A |
7.75 x 4.75 x 2.35 |
8.25 x 3.5 x 9.0 |
7.0 |
1 |
STF0300-24L |
30.0 |
10 |
30A |
37.5A |
7.75 x 4.75 x 2.35 |
8.25 x 3.5 x 9.0 |
8.0 |
1 |
Three-Phase Models (120/208 V WYE)*
Units are standard in NEMA 12 hinged enclosures |
STF0150-10Y |
15.0 |
14 |
15A |
18.75A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
| STF0300-10Y |
30.0 |
10 |
30A |
37.5A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
| STF0500-10Y |
50.0 |
4 |
50A |
62.5A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
| STF1000-10Y |
100.0 |
2 |
100A |
125A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
| STF2000-10Y |
200.0 |
3/0 |
200A |
250A |
20 x 16 x 9 |
25.25 x 14.0 x 26.5 |
110.0 |
2 |
Three-Phase Models (240 Delta)*
Units are standard in NEMA 12 hinged enclosures |
STF0150-24D
|
15.0 |
14 |
15A |
18.75A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0300-24D |
30.0 |
10 |
30A |
37.5A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0500-24D |
50.0 |
4 |
50A |
62.5A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF1000-24D |
100.0 |
2 |
100A |
125A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF2000-24D |
200.0 |
3/0 |
200A |
250A |
20 x 16 x 9 |
25.25 x 14.0 x 26.5 |
110.0 |
2 |
Three-Phase Models (277/480 V WYE)*
Units are standard in NEMA 12 hinged enclosures |
STF0150-27Y
|
15.0 |
14 |
15A |
18.75A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0300-27Y |
30.0 |
10 |
30A |
37.5A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0500-27Y |
50.0 |
4 |
50A |
62.5A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF1000-27Y |
100.0 |
2 |
100A |
125A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF2000-27Y |
200.0 |
3/0 |
200A |
250A |
20 x 16 x 9 |
25.25 x 14.0 x 26.5 |
110.0 |
2 |
Three-Phase Models (480V Delta)*
Units are standard in NEMA 12 hinged enclosures |
STF0150-48D
|
15.0 |
14 |
15A |
18.75A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0300-48D |
30.0 |
10 |
30A |
37.5A |
14 x 12 x 6 |
14.75 x 10.0 x 15.5 |
38.0 |
4 |
STF0500-48D |
50.0 |
4 |
50A |
62.5A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF1000-48D |
100.0 |
2 |
100A |
125A |
20 x 16 x 9 |
21.25 x 10.0 x 22.5 |
85.0 |
2 |
STF2000-48D |
200.0 |
3/0 |
200A |
250A |
20 x 16 x 9 |
25.25 x 14.0 x 26.5 |
110.0 |
2 |
|
 |
Figure 1 |
Figure 2 |

|

|
Figure 3 |
Figure 4 |
What's New |
Products |
Cross Reference |
Technical Support |
Contact Us |
Search |
Surge Protection Home
© 2007
SolaHD. All Rights Reserved.