| SDP-T
Series Specifications |
Click here for a printable copy: |
|
24
Volt Models (see
other voltages in next table below)
|
|
Description
|
Catalog
Number
|
| SDP06-24-100T |
SDP1-24-100T
|
SDP2-24-100T
|
SDP4-24-100RT |
SDP4-24-100LT |
| List
Price ($ USD) |
69.00 |
99.00 |
129.00 |
169.00 |
169.00 |
|
Input
|
| Input
Voltage |
85-264
VAC, 90-375 VDC |
AC
85-132 / 176-264
(Auto Select) or DC 210-375 V |
| Input
Frequency |
43-67
Hz |
| Input
Current |
0.4
A / 0.25A |
0.7A
/ 0.4A |
1.1A
/ 0.7A
|
2.2
A / 1.2 A |
| External
Fusing |
Not
required. Unit provides internal fuse (T3A, not accessible) |
| Hold-Up
Time |
>25
ms |
| Efficiency |
>
80% typ. |
>
83% typ. |
>
86% typ. |
>
88% typ. |
| Losses |
<
3.75 W typ. |
<
6.1 W typ. |
<
8.1 W typ. |
<
12 W typ. |
|
Output
|
| Output Voltage |
24 V (22.5-28.5
VDC adj.)
|
Voltage
Regulation |
Static 0.5% Vout
,
dynamic +2% Vout overall
|
| Ripple/Noise1
|
<
50 mVpp
|
Overvoltage
Protection (OVP) |
>
30 VDC, but < 33 VDC, auto recovery
|
Output
Noise
Suppression |
Radiated
EMI values below EN61000-6-2
|
Rated
Continuous
Loading |
0.63
A @ 24 VDC,
0.54 A @ 28 VDC |
1.3
A @ 24 VDC,
1.1 A @ 28 VDC |
2.1 A @ 24 VDC,
1.8 A @ 28 VDC |
4.2
A @ 24.5 VDC
3.6 A @ 28 VDC |
3.8
A @ 24.5 VDC |
Overload
Behavior |
Continuous
operation at overload/short-circuit: up to 1.5 x Nominal
Current Continuous.
|
| Protection
|
Unit
is continuously protected against short-circuit, overload and
open-circuit.
|
| Power
Back Immunity |
35
V |
|
Installation
|
|
Case
& Mounting
|
Molded
plastic housing using UL 94 approved flameproof material rating
94V-2. Simple snap-on to DINTS35/7.5 or TS35/15 rail system.
|
| Status
Indicators |
Green
LED on when Vout = OK.
|
Dimensions
(in/mm)(H
x W x D) |
2.95
in x 0.9in x 3.8in
75 mm x 22.8 mm x 96.7 mm
|
2.95
in x 1.77 in x 3.58 in
75 mm x 45 mm x 91 mm
|
2.95
in x 2.85 in x 3.8 in
75 mm x 72.55 mm x 96.7 mm
|
| Weight
(lbs/g) |
0.35
lbs (150 g) |
0.5
lbs (240 g) |
0.7
lbs (320 g)
|
Mounting
Orientation |
Standard:
Vertical
Optional: Horizontal or On Top (Contact Technical Services)
|
Ventilation/Cooling
Free space
for cooling |
Normal
convection, no fan reqiured
Above/below: 25 mm recommended
|
Connection
Connector size
range |
Input:
screw terminals, connector size range: 20-12AWG (1.5-6mm2) for
solid or stranded conductors.
|
|
General
|
| Temperature |
Storage:
-25°C...+85°C Operation. -10°-60°C
full power with linear derating to half power from 60°C
to 70°C. (Convection cooling, no forced air required).
|
| MTBF
|
>
500,000 hrs according to Telcordia/Bellcore Document SR-332, Issue
1 |
| Humidity
|
Up
to 90% noncondensing, IEC 68-2-2, 68-2-3
|
Electromagnetic
Emissions (EME) |
EN
61000-6-3 (includes EN 61000-6-4) Class B (EN 55022) incl. Annex
A
|
Electromagnetic
Immunity (EMI) |
EN
61000-6-2 (Includes EN 61000-6-1) (EN55024) Criterion A: no degradation
of performance.
|
| Safe
Low Voltage |
SELV
(acc.EN60950) |
Prot.
Class/
Voltage |
IP20
(IEC529), Protection Class 1 (IEC536)
|
| Warranty
|
3
years
|
|
Safety
|
| CB
Scheme, EN60950, EN50178, EN60204, EN60079-15 (Class 1, Zone 2 Hazardous
Locations, Temp Class T3), UL508 Listed, cULus, UL 60950, cURus,
CE (LVD 73/23 & 93/68/EEC). (EMC 89/336 & 93/68/EEC). EN61000-3-2,
NEC Class 2 power supply acc. To NFPA 70 art. 725-41 (a)(2).2 |
| Note:
1. Ripple/noise is stated as typical values when measured
with a 20 MHz, bandwidth scope and 50 Ohm resistor.
2. For models less than 100W.
|
|
Description
|
Catalog
Number |
|
SDP
5-5-100T
|
SDP
2-12-100T |
SDP
3-15-100T |
SDP1-48-100T
|
| List
Price ($USD) |
110.00 |
123.00 |
136.00 |
124.00 |
|
Input
|
| Input
Voltage |
85-264
VAC, 90-375 VDC |
| Input
Frequency |
43-67
Hz |
| Input
Current |
0.6A
@ 102 VAC
0.33A @ 196 VAC |
<1.0
A @ 102 VAC
<0.6 A @ 196 VAC |
<1.0
A @ 100 VAC
<0.6 A @ 196 VAC
|
| External
Fusing |
Not
required. Unit provides internal fuse (T3A, not accessible) |
| Hold-Up
Time |
>
25 ms |
| Efficiency |
>
80% typ. |
>
86% typ. |
90%
typ. |
| Losses |
7.5 W typ. |
8.1W typ. |
|
Output
|
Output
Voltage |
5-5.5
VDC (5-6 min adj.) |
12
VDC (9.9-12.1 min adj.) |
15
VDC (11.9-15.1 min adj.) |
48
VDC (48-56 min adj.) |
Voltage
Regulation |
<
2& Dynamic; < 0.5% Static
|
| Ripple/Noise1
|
<
50 mVpp
|
Overvoltage
Protection (OVP) |
<
6.7 VDC |
<
18 VDC
|
<
20 VDC
|
<
60 VDC
|
Output
Noise
Suppression |
Radiated
EMI values below EN61000-6-2
|
Rated
Continuous
Loading |
Iout
5A @
Vout = 5.1 V |
3
A @ 10 VDC,
2.5 A @ 12 VDC |
4.2
A @ 12 VDC,
3.4 A @ 15 VDC |
Up to 1.05 A @ 48 V
0.9 A @ 56 V |
Overload
Behavior |
Continuous
operation at overload/short-circuit: up to 1.5x Nominal Current
Continuous.
|
| Protection
|
Unit is continuously protected against short-circuit,
overload and open-circuit.
|
Power
Back
Immunity |
10
V |
22
V |
80
V |
|
Installation
|
| Case
& Mounting |
Molded
plastic housing using UL 94 approved flameproof material rating
94V-2. Simple snap-on to DINTS35/7.5 or TS35/15 rail system.
|
| Status
Indicators |
Green
LED on when Vout = OK.
|
Dimensions
(in/mm) (H x W x D) |
2.95
in. x 1.77 in. x 3.58 in.
75mm x 45 mm x 91mm
|
| Weight
(lbs/g) |
0.5
lbs (240 g) |
Mounting
Orientation |
Standard:
Vertical
Optional: Horizontal or On Top (Contact Technical Services).
|
Ventilation/Cooling
Free space for cooling |
Normal
convection, no fan reqiured.
Above/below: 25 mm recommended.
|
Connection
Connector size range |
Input:
screw terminals, connector size range: 20-12 AWG (1.5-6mm2)
for solid or stranded conductors.
|
|
General
|
| Temperature |
Storage:
-25°C...+85°C Operation. -10°-60°C
full power with operation to 70°C possible
with a linear derating to half power from 60°C
to 70°C. (Convection cooling, no forced air required).
|
| MTBF
|
>
500,000 hours according to Telcordia/Bellcore Document SR-332,
Issue 1
|
| Humidity
|
Up
to 90% RH, noncondensing, IEC 68-2-2, 68-2-3
|
Electromagnetic
Emissions (EME) |
EN
61000-6-3 (includes EN 61000-6-4) Class B (EN 55022) incl. Annex
A
|
Electromagnetic
Immunity (EMI) |
EN
61000-6-2 (Includes EN 61000-6-1) (EN55024) Criterion A: no
degradation of performance.
|
| Safe
Low Voltage |
SELV
(acc. EN60950)
|
Prot.
Class/
Voltage |
IP20
(IEC529), Protection Class 1 (IEC536)
|
| Warranty
|
3
years
|
|
Safety
|
|
CB Scheme, EN60950, EN50178, EN60204, EN60079-15 (Class
1, Zone 2 Hazardous Locations, Temp Class T3), UL508 Listed, cULus,
UL 60950, cURus, CE (LVD 73/23 & 93/68/EEC). (EMC 89/336
& 93/68/EEC). EN61000-3-2, NEC Class 2 power supply acc. To
NFPA 70 art. 725-41 (a)(2). |
Notes:
1. Ripple/noise is stated as typical values when measured
with a 20 MHz, bandwidth scope and 50 Ohm resistor.
2. Not to exceed 30 watts total.
|
What's New | Products | Cross Reference |
Technical Support | Contact Us | Search
| Home
Copyright