GL20, GL40 |
GL50 |
GL60, GL110 |
GLQ120, GLS120 |
GL140 |
GL150 |
GL170 |
GL250, GL350 |
GL500 |
|
Input |
|||||||||
| Input Voltage (1) |
85-264 Vac; |
90 - 264 Vac 127 - 300 Vdc |
85 - 264 Vac; 120 - 300 Vdc |
85-132 Vac or 170-264 Vac auto-selected.220-300 Vdc |
85-264 Vac; 120-300 Vdc |
85 - 264 Vac |
|||
Frequency |
47-63 Hz , 400± 40 Hz |
47-63 Hz |
|||||||
Inrush |
GL20: <15A peak GL40: <18A peak |
<60A peak |
<18A peak @ 115 Vac, cold start @ 25°C |
GLQ120: GLS120: |
38 A max, cold start @ 25°C |
GL250: GL350: |
50 A max., cold start @ 25°C |
||
Efficiency |
70% typical |
80% - 85% |
70% typical |
GLQ120: 65% typical at full load. GLS120: 80% typical at full load |
75% typical at full load |
85% typical at full load, nominal line |
|||
EMI/RFI |
FCC Class B ; CISPR 22 Class B ; EN55022 Class B |
||||||||
Safety |
Non-Medical: <0.5 mA @ 50/60 Hz, |
Non-medical: <0.5mA Medical: 275 µA @ 50/60 Hz; 264 Vac input for Class I; <0.25mA @ 50/60 Hz; 264 Vac input for Class II (for single output only) |
Non-Medical: <0.5 mA |
GLQ120: |
1.0 mA @ 50/60 Hz, 264 Vac input |
<0.5 mA |
Non-Medical: 0.1 mA < 250 µA 1.0 mA@ 50/60 Hz, 264 Vac input |
<0.5 mA @ 50/60 Hz, 264 Vac input |
Non-Medical: <0.5 mA Medical: <0.3mA |
Output |
|||||||||
Power |
Refer to the selection table |
||||||||
Adjustment |
-5, +10% |
±20% minimum for GLS50 |
GL60: -5, +10% minimum GL110: ±5% minimum |
±5% minimum |
3.3 - 5.5V on main; -12 - 15V on 3rd output 3.3 - 25 V on 4th output |
±5% minimum |
2:1 wide ratio minimum |
2:1 wide ratio |
±5% |
Hold-up |
20 ms @ full load, 115Vac nominal line |
10/20 ms 115/230 Vac Input line |
20 ms @ full load, 115 Vac nominal line |
||||||
Overload |
Short circuit protection on all outputs. Primary overload protection |
||||||||
Overvoltage Protection |
5V output; 5.7 to |
30-50% above nominal output |
5 V output; 5.7 - 6.7 Vdc. Other outputs 10% to 25% above nominal output |
3.3 V and 5 V output: 20% to 35% above nominal output |
Tracks outputs 1, 3 & 4; 10 to 35% |
5 V output: 5.7 |
10% to 40% above nominal output |
5 V output: 5.7 |
20-35% above nominal output |
Remote Sense |
Compensates for 0.5 V lead drop minimum; Will operate without remote sense connected, Reverse connection protected |
||||||||
General |
|||||||||
Temperature (2) |
Storage: -40°C to +85°C; Operating: 0° to 50°C ambient. Derate each output 2.5% per degree from 50° to 70°C, -20°C start up. |
||||||||
Electro-magnetic Susceptibility |
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 or EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3 |
||||||||
Humidity |
Operating; non-condensing up to 95% RH |
||||||||
| Vibration | Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500 Hz (2 G peak 8 Hz to 500 Hz for GL500) |
||||||||
| MTBF | >550,000 hours demonstrated at full load and 25°C ambient conditions |
||||||||
Safety |
Non-Medical: EN60950, UL UL60950 E132002, CSA CSA 22.2-234 Level 3 LR53982C, CB Certificate and report; CE Mark (LVD) |
||||||||
Notes: